Page 97 - วารสารกรมการแพทย์แผนไทยฯ ปีที่ 14 ฉบับที่ 3
P. 97

315




              method where the extraction is facilitated by  samples tested were within their expiration

              the use of ultrasound. The plant sample is  dates at the time of testing.
              placed in an ultrasonic bath and ultrasound     Chemicals
              is used to induce a mechanical stress on the    Andrographolide Reference Standard

              cells through the production of cavitations in  (Lot F0I344) was purchased from U.S. Phar-
              the sample. The cellular breakdown increases  macopoeia, USA. HPLC- and AR- grade of
              the solubilization of metabolites in the sol-  methanol were obtained from Macron Fine

              vent, improves extraction yields and reduced  Chemicals (USA) while dichloromethane was
              extraction time. Furthermore, ultrasonic bath  from Mallinckrodt (USA). Ultrapure water ge-

              is the apparatus available in all quality con-  nerated by Milli-Q (Millipore Corporation,
              trol testing laboratories with typical labora-  USA) was used.
              tory applications of dissolving the standards   Apparatus

              and degassing of HPLC solvents. There were      Reflux extraction apparatus, Rotary
              also some reports on quantitative analysis of  evaporator (Eyela, Japan), Water bath

              andrographolide in Andrographis herb, ex-  (NESLAB, USA), Ultrasonic bath (Elmasonic,
              tracts and dosage forms in which ultraso-  Germany), High Performance Liquid Chroma-
                                        [27-31]
              nication was used frequently.              tography equipped with UV detector (Waters,
                  The objectives of this study were to com-  USA), Micro balance and analytical balance
              pare the extraction efficiency of ultraso-  (Mettler Toledo, Switzerland), Sieve No. 180
              nication and reflux extraction methods and  (nominal mesh aperture size of 180 mm,

              to propose an alternative to the current THP  Endecotts, England)
              method for quality control of Andrographis
                                                         Method
              capsules.
                                                              1. Sample Preparation
                           Methodology
                                                                 1.1 Reflux extraction
              Material                                                              [24]
                                                                 As described in THP , remove, as
                  Sample                                 completely as possible, the contents of not
                  A total of 30 different lots of Andro-  less than 20 Fa-Tha-Lai capsules, and grind

              graphis capsules from 17 manufacturers were  to No. 180 powder. Transfer about 400 mg,
              used in this study. The strength of Andro-  accurately weighed, to a 100 mL round bot-

              graphis capsules tested was 250, 350, 400,  tom flask. Add 50 mL of a mixture of equal
              450, and 500 mg of powdered form. All      volumes of dichloromethane and methanol,
   92   93   94   95   96   97   98   99   100   101   102