Page 103 - วารสารกรมการแพทย์แผนไทยฯ ปีที่ 14 ฉบับที่ 3
P. 103

321




              to prepare the sample solutions for com-   tion method described in THP, it has various

              paring the extraction efficiency with that of  drawbacks, such as time-consuming, labor-
              reflux extraction method which is a standard  intensive and multi-step process that requires
              preparation method described in the THP.   concentration by solvent evaporation before

                  According to ICH Q2(R1) Validation of  chromatographic analysis. Long sample pre-
              Analytical Procedures, change in sample    paration times limit the number of samples,
              preparation requires partial validation to en-  and multi-step procedures are prone to intro-

              sure that the analytical method maintains its  duce errors and loss of analytes. The signi-
              characteristics. Change in sample prepara-  ficant advantages of ultrasonication over reflux

              tion did not have an effect on the analytical  method are reduction of organic solvent con-
              method performance and data integrity as   sumption, elimination of additional concen-
              confirmed by validation results on speci-  tration step and improvement in extraction

              ficity, linearity, accuracy and precision. All  efficiency. Therefore, ultrasound-assisted ex-
              validated parameters were within the accep-  traction is an attractive alternative to con-

              tance criteria.                            ventional extraction techniques because it is
                  The contents of andrographolide ex-    easy, inexpensive, fast and efficient. The pro-
              tracted using ultrasonication were comparable  posed sample preparation technique was also

              and in most cases they are even higher than  applied to determine the andrographolide
              those obtained from reflux method. These   content in Andrographis herbal materials as
              results indicated that the extraction efficiency  well as Andrographis extract capsules. It is

              of reflux method using a mixture of methanol  found that raw materials have satisfied quali-
              and dichloromethane is not as efficient as  ty in terms of andrographolide content (1.64-
              that obtained from ultrasonication with 50%  2.14 %w/w) and the extract capsule contains

              methanol. However, there were two samples  andrographolide as high as 7.38 %w/w.
              that reflux method gave higher content of
                                                                       Conclusion
              extracted andrographolide. These were fur-
              ther investigated and it was found that the     Two sample preparation techniques
              particle sizes of sample powder were not   were compared in this study. The results

              uniform even they were finely ground and   clearly indicated that ultrasonication was
              sieved through mesh size No.180, small stem  better than reflux extraction method because

              parts were also observed. Although reflux  it provides higher extraction efficiency, was
              extraction is the standard sample prepara-  more economical, more convenient, easily
   98   99   100   101   102   103   104   105   106   107   108